Manufacturer | Model | Confirmed | Driver Notes |
---|---|---|---|
01dB (ACOEM) | |||
CUBE | X | Custom HTTP - It is recommended that only one logger logs data from the instrument at a time. Multiple data loggers may interfere unless they are requesting the same parameters on every poll. Polling performance is significantly reduced when requesting over 30 real-time values or 6 weather values. | |
DUO | X | ||
FUSION | X | ||
Aethlabs | |||
microAeth® / MA350 | Support being added | ||
Ambilabs | |||
2-WIN (Integrating Nephelometer) | |||
AMETEK MOCON | |||
Baseline 9000 MNME | |||
Baseline 9100 GC | X | ASCII Protocol | |
Bayern-Hessen (Generic) | |||
Generic Bayern-Hessen allows a user to define their own parameters for an instrument that supports the Bayern-Hessen protocol. Parameter IDs must be numeric, and not prefixed with ‘MD’. | |||
BMET | |||
Neph 2100/2300/2400 Gas Analyser | |||
Dani | |||
TNMH 462 | Not yet supported | ||
Ecotech | |||
9400 Termination Panel | X | Can only handle one-second polling for a small number of parameters. Polling interval may need to be increased if polling a large number of parameters. | |
ACS 1000 | X | Ecotech Advanced Protocol | |
Aurora Nephelometer | X | Use “Multi-Drop” protocol on multi-drop port for regular polling | |
EC98xx Gas Analyser | X | Ecotech Advanced Protocol Original Protocol | |
Exactus BAM Particulate Monitor | Computer Protocol (Network Id supported) | ||
GasCal Calibrator Series1000/1100/1100 FS/1100 TS | GasCal Protocol | ||
HiVol Dust Sampler | X | ||
M9003 Nephelometer | X | ||
MicroVol Dust Sampler | X | ||
MicroVol Weather Station | X | ||
Protinus 1000 Particulate Monitor | Computer Protocol (Network Id supported) | ||
Serinus Gas Analyser10/30/31/40/44/50/51/55/56/57/60 | X | Ecotech Advanced Protocol | |
Serinus Cal Series Calibrators1000/2000/300/3000 | X | Ecotech Advanced Protocol | |
Spirant BAM Particulate MonitorBAM1000 (PM10)/BAM1100 (PM2.5) | X | User mode ASCII Protocol | |
VOC 1000 | ASCII Pushed Protocol | ||
Environics | |||
6100 Calibrator | Support being added | ||
Environnement S.A. | |||
AC31M/AC32M | X | MODE4/MODE4+ | |
AF21M/AF22M | X | MODE4/MODE4+ | |
AS32M | MODE4/MODE4+ | ||
CO11M/CO12M | X | MODE4/MODE4+ | |
HC51M | X | MODE4/MODE4+ | |
MP101M | MODE4/MODE4+ | ||
O₃41M/O₃42M | X | MODE4/MODE4+ | |
VOC71M | MODE4/MODE4+ | ||
Gill | |||
Maximet GMX500 | X | Modbus. Must be non-GPS model on default register settings. | |
WindSonic | X | Supports all message formats (UV/Polar/NMEA) in continuous and polled mode. | |
Grimm | |||
EDM 180 | |||
ICP DAS | |||
I7000 Series7005/7017/7021/7022/7024/7024R/7024U | X | DCON Protocol | |
LCJ Capteurs | |||
Wind Sensor | X | NMEA 0183 Template | |
Los Gatos Research | |||
Greenhouse Gas Analyser | |||
Magee Scientific | |||
Aethalometer Model AE33 |
|
| |
Met One Instruments Inc. | |||
BAM 1020 Particulate Monitor | X | Computer Protocol (Network Id supported) | |
BAM 1022 | X | Computer Protocol (Network Id supported) Tested with firmware 81650, R1.0.7 | |
BC 1054 | X | ASCII MetRecord Protocol tested with firmware 82401 R3.1.0 on Serial - Note that adding an instrument id automatically switches the protocol to network mode | |
E-642 Dust Monitor | Computer Protocol (Network Id supported) Not Currently Avialable | ||
E-BAM Particulate Monitor | X | Computer Protocol (Network Id supported) Tested with firmware 3613-01 R1.57 | |
E-BAM PLUS Particulate Monitor | X | Computer Protocol (Network Id supported) Tested with firmware 82102, R1.0.0/82102, R1.1.3/82102, R1.3.0 | |
E-SAMPLER Particulate Monitor | X | Computer Protocol (Network Id supported) Tested with firmware 3693-01 R1.19.5/3693-01 R1.19.8/3693-02 R2.0.3/3693-02 R2.0.5 | |
Modbus (Generic) | RTU/TCP | ||
Generic modbus (RTU and TCP) allows a user to define their own register configuration by manually adding user defined parameters for a variety of supported function codes and with the ability to specify the byte order at the instrument level. | |||
Opsis | |||
AR600/AR650/LD500 | |||
Palas | |||
Fidas 200 | Modbus Template | ||
Picarro | |||
G1301 | |||
G4x | |||
Rupprecht and Patashnick (R&P) | |||
TEOM 1400a | X | AK Protocol | |
Synspec | |||
GC955 | |||
Teledyne API | |||
Gas Analyzer | X | Multi-drop protocol. Tested on T100, T200 and T400 | |
Gas Calibrator | X | Multi-drop protocol. Tested on T700 and T700U | |
Thermo Fisher | |||
42i/43i/48i/49i | X | C-Link | |
5014i | X | C-Link Modbus Template | |
5028i | X | C-Link Modbus Template | |
5030 | |||
5030i | |||
FH62C14 | X | ||
Partisol 2025 | C-Link Bayern-Hessen Template Modbus Template Needs testing (also supports AK protocol - not implemented) | ||
Sharp 5030 | Support being added | ||
TEOM 1400a/1405/1405DF | X | AK Protocol | |
Vaisala | |||
H425 | Support being added | ||
PTB220 | X | ASCII Protocol | |
WMT700 | Can use WS425 ASCII driver with the WS425 - ASCII profile | ||
WS425 | ASCII Protocol | ||
WXT 510 | X | ASCII Protocol | |
WXT 520 | X | ASCII Protocol | |
WXT 530 Series | X | NMEA Protocol | |
Verewa | |||
F-701-20 | |||
Yoctopuce | |||
Yocto-WatchdogDC (Ecotech Congrego Watchdog) | X | Use “custom” connection. | |
Zetian | |||
DPM-6000 | Modbus Template |
...