Manufacturer

Model

Confirmed

Driver Notes

01dB (ACOEM)

CUBE

X

Custom HTTP - It is recommended that only one logger logs data from the instrument at a time. Multiple data loggers may interfere unless they are requesting the same parameters on every poll.

Polling performance is significantly reduced when requesting over 30 real-time values or 6 weather values.

DUO

X

FUSION

X

Aethlabs

microAeth® / MA350

Support being added

Ambilabs

2-WIN (Integrating Nephelometer)

AMETEK MOCON

Baseline 9000 MNME

Baseline 9100 GC

X

ASCII Protocol
Parameter ID is first two fields concatenated with an underscore (e.g. “Pt1_Et0”). Newly discovered parameters are logged in Kryptonite.

Bayern-Hessen (Generic)

Generic Bayern-Hessen allows a user to define their own parameters for an instrument that supports the Bayern-Hessen protocol. Parameter IDs must be numeric, and not prefixed with ‘MD’.

BMET

Neph 2100/2300/2400 Gas Analyser

Dani

TNMH 462

Not yet supported

Ecotech

9400 Termination Panel

X

Can only handle one-second polling for a small number of parameters. Polling interval may need to be increased if polling a large number of parameters.

ACS 1000

X

Ecotech Advanced Protocol

Aurora Nephelometer

X

Use “Multi-Drop” protocol on multi-drop port for regular polling
Use “Remote Menu” protocol on service port for remote screen

EC98xx Gas Analyser

X

Ecotech Advanced Protocol

Original Protocol

Exactus BAM Particulate Monitor

Computer Protocol (Network Id supported)

GasCal Calibrator Series

1000/1100/1100 FS/1100 TS

GasCal Protocol

HiVol Dust Sampler

X

M9003 Nephelometer

X

MicroVol Dust Sampler

X

MicroVol Weather Station

X

Protinus 1000 Particulate Monitor

Computer Protocol (Network Id supported)

Serinus Gas Analyser

10/30/31/40/44/50/51/55/56/57/60

X

Ecotech Advanced Protocol

Serinus Cal Series Calibrators

1000/2000/300/3000

X

Ecotech Advanced Protocol

Spirant BAM Particulate Monitor

BAM1000 (PM10)/BAM1100 (PM2.5)

X

User mode ASCII Protocol

VOC 1000

ASCII Pushed Protocol

Environics

6100 Calibrator

Support being added

Environnement S.A.

AC31M/AC32M

X

MODE4/MODE4+

AF21M/AF22M

X

MODE4/MODE4+

AS32M

MODE4/MODE4+

CO11M/CO12M

X

MODE4/MODE4+

HC51M

X

MODE4/MODE4+

MP101M

MODE4/MODE4+

O₃41M/O₃42M

X

MODE4/MODE4+

VOC71M

MODE4/MODE4+

Gill

Maximet GMX500

X

Modbus. Must be non-GPS model on default register settings.

WindSonic

X

Supports all message formats (UV/Polar/NMEA) in continuous and polled mode.
Set the device ID (A to Z) to poll the instrument, or leave blank for continuous mode.

Grimm

EDM 180

Gesytec Protocol

ICP DAS

I7000 Series

7005/7017/7021/7022/7024/7024R/7024U

X

DCON Protocol

LCJ Capteurs

Wind Sensor

X

NMEA 0183 Template

Los Gatos Research

Greenhouse Gas Analyser

Magee Scientific

Aethalometer Model AE33

  • X

  • X

  • -

    • X

    • -

    • -

  • Pushed Data Protocol - AE33_data streaming (ID_com=9)

  • Polled Data Protocol - Datalogger_AE33_protocol (ID_com = 5)

  • Bayern-Hessen

    • BH Protocol - Datalogger_BH_protocol (ID_com = 7)

    • BH Protocol 2 - Datalogger_BH_protocol (ID_com = 12)

    • BH Protocol 3 - Datalogger_BH_protocol (ID_com = 13)

Met One Instruments Inc.

BAM 1020 Particulate Monitor - 9800

X

Computer Protocol (Network Id supported)

9803 Touch Screen Variant should also be supported

BAM 1020 Particulate Monitor - 9805

X

Computer Protocol (Network Id supported)

Minimum firmware required: TBD

BAM 1022

X

Computer Protocol (Network Id supported)

Tested with firmware 81650, R1.0.7

BC 1054

X

ASCII

MetRecord Protocol tested with firmware 82401 R3.1.0 on Serial - Note that adding an instrument id automatically switches the protocol to network mode

E-642 Dust Monitor

Computer Protocol (Network Id supported)

Not Currently AvialableAvailable

E-BAM Particulate Monitor

X

Computer Protocol (Network Id supported)

Tested with firmware 3613-01 R1.57

E-BAM PLUS Particulate Monitor

X

Computer Protocol (Network Id supported)

Tested with firmware 82102, R1.0.0/82102, R1.1.3/82102, R1.3.0

E-SAMPLER Particulate Monitor

X

Computer Protocol (Network Id supported)

Tested with firmware 3693-01 R1.19.5/3693-01 R1.19.8/3693-02 R2.0.3/3693-02 R2.0.5

Modbus (Generic)

RTU/TCP

Generic modbus (RTU and TCP) allows a user to define their own register configuration by manually adding user defined parameters for a variety of supported function codes and with the ability to specify the byte order at the instrument level.

Opsis

AR600/AR650/LD500

Palas

Fidas 200

Modbus Template

Picarro

G1301

G4x

Rupprecht and Patashnick (R&P)

TEOM 1400a

X

AK Protocol

Synspec

GC955

Teledyne API

Gas Analyzer

X

Multi-drop protocol. Tested on T100, T200 and T400

Gas Calibrator

X

Multi-drop protocol. Tested on T700 and T700U

Thermo Fisher

42i/43i/48i/49i

X

C-Link

5014i

X

C-Link

ESM ASCII Protocol

Modbus Template

5028i

X

C-Link

Modbus Template

5030

ESM ASCII Protocol

5030i

ESM ASCII Protocol

FH62C14

X

ESM ASCII Protocol

Partisol 2025

C-Link

Bayern-Hessen Template

Modbus Template

Needs testing (also supports AK protocol - not implemented)

Sharp 5030

Support being added

TEOM 1400a/1405/1405DF

X

AK Protocol

Vaisala

H425

Support being added

PTB220

X

ASCII Protocol

WMT700

Can use WS425 ASCII driver with the WS425 - ASCII profile

WS425

ASCII Protocol

WXT 510

X

ASCII Protocol

WXT 520

X

ASCII Protocol

WXT 530 Series

X

NMEA Protocol

Verewa

F-701-20

Yoctopuce

Yocto-WatchdogDC (Ecotech Congrego Watchdog)

X

Use “custom” connection.

Zetian

DPM-6000

Modbus Template

...