Congrego Drivers
Definitions:
Confirmed - Denotes that the driver has been tested against an actual instrument, during development an instrument may not be available for testing.
Modbus Template - Modbus supported and a template provided with preconfigured registers
|
|
|
|
01dB (ACOEM) |
|
|
|
| CUBE | X | Custom HTTP - It is recommended that only one logger logs data from the instrument at a time. Multiple data loggers may interfere unless they are requesting the same parameters on every poll. Polling performance is significantly reduced when requesting over 30 real-time values or 6 weather values. |
| DUO | X | |
| FUSION | X | |
Aethlabs |
|
|
|
| microAeth® / MA350 |
| Support being added |
|
|
|
|
Ambilabs |
|
|
|
| 2-WIN (Integrating Nephelometer) |
|
|
|
|
|
|
AMETEK MOCON |
|
|
|
| Baseline 9000 MNME |
|
|
| Baseline 9100 GC | X | ASCII Protocol |
|
|
|
|
Bayern-Hessen (Generic) |
|
|
|
|
|
| Generic Bayern-Hessen allows a user to define their own parameters for an instrument that supports the Bayern-Hessen protocol. Parameter IDs must be numeric, and not prefixed with ‘MD’. |
BMET |
|
|
|
| Neph 2100/2300/2400 Gas Analyser |
|
|
|
|
|
|
Dani |
|
|
|
| TNMH 462 |
| Not yet supported |
|
|
|
|
Ecotech |
|
|
|
| 9400 Termination Panel | X | Can only handle one-second polling for a small number of parameters. Polling interval may need to be increased if polling a large number of parameters. |
| ACS 1000 | X | Ecotech Advanced Protocol |
| Aurora Nephelometer | X | Use “Multi-Drop” protocol on multi-drop port for regular polling |
| EC98xx Gas Analyser | X | Ecotech Advanced Protocol Original Protocol |
| Exactus BAM Particulate Monitor |
| Computer Protocol (Network Id supported) |
| GasCal Calibrator Series1000/1100/1100 FS/1100 TS |
| GasCal Protocol |
| HiVol Dust Sampler | X |
|
| M9003 Nephelometer | X |
|
| MicroVol Dust Sampler | X |
|
| MicroVol Weather Station | X |
|
| Protinus 1000 Particulate Monitor |
| Computer Protocol (Network Id supported) |
| Serinus Gas Analyser10/30/31/40/44/50/51/55/56/57/60 | X | Ecotech Advanced Protocol |
| Serinus Cal Series Calibrators1000/2000/300/3000 | X | Ecotech Advanced Protocol |
| Spirant BAM Particulate MonitorBAM1000 (PM10)/BAM1100 (PM2.5) | X | User mode ASCII Protocol |
| VOC 1000 |
| ASCII Pushed Protocol |
|
|
|
|
Environics |
|
|
|
| 6100 Calibrator |
| Support being added |
|
|
|
|
Environnement S.A. |
|
|
|
| AC31M/AC32M | X | MODE4/MODE4+ |
| AF21M/AF22M | X | MODE4/MODE4+ |
| AS32M |
| MODE4/MODE4+ |
| CO11M/CO12M | X | MODE4/MODE4+ |
| HC51M | X | MODE4/MODE4+ |
| MP101M |
| MODE4/MODE4+ |
| O₃41M/O₃42M | X | MODE4/MODE4+ |
| VOC71M |
| MODE4/MODE4+ |
Gill |
|
|
|
| Maximet GMX500 | X | Modbus. Must be non-GPS model on default register settings. |
| WindSonic | X | Supports all message formats (UV/Polar/NMEA) in continuous and polled mode. |
|
|
|
|
Grimm |
|
|
|
| EDM 180 |
| |
|
|
|
|
ICP DAS |
|
|
|
| I7000 Series7005/7017/7021/7022/7024/7024R/7024U | X | DCON Protocol |
|
|
|
|
LCJ Capteurs |
|
|
|
| Wind Sensor | X | NMEA 0183 Template |
|
|
|
|
Los Gatos Research |
|
|
|
| Greenhouse Gas Analyser |
|
|
|
|
|
|
Magee Scientific |
|
|
|
| Aethalometer Model AE33 |
|
|
|
|
|
|
Met One Instruments Inc. |
|
|
|
| BAM 1020 Particulate Monitor - 9800 | X | Computer Protocol (Network Id supported) 9803 Touch Screen Variant should also be supported |
| BAM 1020 Particulate Monitor - 9805 | X | Computer Protocol (Network Id supported) Minimum firmware required: TBD |
| BAM 1022 | X | Computer Protocol (Network Id supported) Tested with firmware 81650, R1.0.7 |
| BC 1054 |
X | ASCII MetRecord Protocol tested with firmware 82401 R3.1.0 on Serial - Note that adding an instrument id automatically switches the protocol to network mode |
| E-642 Dust Monitor |
| Computer Protocol (Network Id supported) Not Currently Available |
| E-BAM Particulate Monitor | X | Computer Protocol (Network Id supported) Tested with firmware 3613-01 R1.57 |
| E-BAM PLUS Particulate Monitor | X | Computer Protocol (Network Id supported) Tested with firmware 82102, R1.0.0/82102, R1.1.3/82102, R1.3.0 |
| E-SAMPLER Particulate Monitor | X | Computer Protocol (Network Id supported) Tested with firmware 3693-01 R1.19.5/3693-01 R1.19.8/3693-02 R2.0.3/3693-02 R2.0.5 |
Modbus (Generic) | RTU/TCP |
|
|
|
|
| Generic modbus (RTU and TCP) allows a user to define their own register configuration by manually adding user defined parameters for a variety of supported function codes and with the ability to specify the byte order at the instrument level. |
Opsis |
|
|
|
| AR600/AR650/LD500 |
|
|
|
|
|
|
Palas |
|
|
|
| Fidas 200 |
| Modbus Template |
|
|
|
|
Picarro |
|
|
|
| G1301 |
|
|
| G4x |
|
|
|
|
|
|
Rupprecht and Patashnick (R&P) |
|
|
|
| TEOM 1400a | X | AK Protocol |
|
|
|
|
Synspec |
|
|
|
| GC955 |
|
|
|
|
|
|
Teledyne API |
|
|
|
| Gas Analyzer | X | Multi-drop protocol. Tested on T100, T200 and T400 |
| Gas Calibrator | X | Multi-drop protocol. Tested on T700 and T700U |
|
|
|
|
Thermo Fisher |
|
|
|
| 42i/43i/48i/49i | X | C-Link |
| 5014i | X | C-Link Modbus Template |
| 5028i | X | C-Link Modbus Template |
| 5030 |
| |
| 5030i |
| |
| FH62C14 | X | |
| Partisol 2025 |
| C-Link Bayern-Hessen Template Modbus Template Needs testing (also supports AK protocol - not implemented) |
| Sharp 5030 |
| Support being added |
| TEOM 1400a/1405/1405DF | X | AK Protocol |
|
|
|
|
Vaisala |
|
|
|
| H425 |
| Support being added |
| PTB220 | X | ASCII Protocol |
| WMT700 |
| Can use WS425 ASCII driver with the WS425 - ASCII profile |
| WS425 |
| ASCII Protocol |
| WXT 510 | X | ASCII Protocol |
| WXT 520 | X | ASCII Protocol |
| WXT 530 Series | X | NMEA Protocol |
Verewa |
|
|
|
| F-701-20 |
|
|
|
|
|
|
Yoctopuce |
|
|
|
| Yocto-WatchdogDC (Ecotech Congrego Watchdog) | X | Use “custom” connection. |
|
|
|
|
Zetian |
|
|
|
| DPM-6000 |
| Modbus Template |