Definitions:

Confirmed - Denotes that the driver has been tested against an actual instrument, during development an instrument may not be available for testing.

Modbus Template - Modbus supported and a template provided with preconfigured registers

Manufacturer

Model

Driver Notes

ACOEM

01dB CUBE

HTTP request notes.

01dB DUO

01dB FUSION

01dB ORION

HTTP request notes.

Aethlabs

microAeth® MA200

Black Carbon Monitor

  • Serial communication

microAeth® MA300

Black Carbon Monitor

  • Serial communication

microAeth® MA350

Black Carbon Monitor

  • Serial communication

AMA Instruments

GC5000 BTX

Gas Chromatograph

  • Gesytec II protocol

Ambilabs

2-WIN (Integrating Nephelometer)

Two Wavelength Integrating Nephelometer

AMETEK MOCON

Baseline 9000 MNME

Methane/Non-Methane analyser with flame ionization detector (FID)

Baseline 9100 GC

Gas Chromatograph

  • ASCII Protocol
    Parameter ID is first two fields concatenated with an underscore (e.g. “Pt1_Et0”). Newly discovered parameters are logged in Kryptonite.

Bayern-Hessen (Generic)

Generic Bayern-Hessen allows a user to define their own parameters for an instrument that supports the Bayern-Hessen protocol. Parameter IDs must be numeric, and not prefixed with ‘MD’.

BMET

Neph 2100/2300/2400 Gas Analyser

Ecotech

9400 Termination Panel

Termination Panel

  • Can only handle one-second polling for a small number of parameters.

  • Polling interval may need to be increased if polling a large number of parameters.

ACS 1000

Aerosol Conditioning System

  • Uses the Acoem Advanced Protocol

Aurora 1000/3000/4000 Nephelometer

1000 - Integrating Nephelometer

2000 - PM2.5 Correlating Nephelometer

3000 - 3 wavelength Integrating Nephelometer

  • Use “Multi-Drop” protocol on multi-drop port for regular polling

  • Use “Remote Menu” protocol on service port for remote screen

Aurora NE-100/NE-300/NE-400

100 - Integrating Nephelometer

300 - Integrating Nephelometer

400 - Polar Integrating Nephelometer

EC98xx Gas Analyser

Ecotech Advanced Protocol

Original Protocol

Exactus BAM Particulate Monitor

Real-time particulate monitor

  • Computer Protocol (Network Id supported)

GasCal Calibrator Series

1000/1100/1100 FS/1100 TS

1000

1100 Dilution Calibrator

100FS

100TS

  • GasCal Protocol

HiVol 3000

High volume air sampler

M9003 Nephelometer

MicroVol Dust Sampler

Low volume air sampler

MicroVol Weather Station

Weather Station

Protinus 1000 Particulate Monitor

Real-time dust monitor

  • Computer Protocol (Network Id supported)

Serinus Gas Analyser

Sxx series of analysers

10 Ozone (O3) Analyser

30 Carbon Monoxide (CO) Analyser

31 Carbon Dioxide (CO2) Analyser

40 Oxides of Nitrogen (NOx) Analyser

44 Ammonia Analyser

50 Sulfur Dioxide (SO2) Analyser

51 Hydrogen Sulfide and Sulfur Dioxide Analyser

55 Hydrogen Sulfide (H2S) Analyser

56 Total Sulfur Analyser

57 Total Reduced Sulfur (TRS) Analyser

60 Direct Nitrogen Dioxide (NO2) Analyser

  • Acoem Advanced Protocol

Serinus Cal Series Calibrators

1000/2000/300/3000

Ecotech Advanced Protocol

Spirant BAM Particulate Monitor

BAM1000 (PM10)/BAM1100 (PM2.5)

Particulate monitor

  • User mode ASCII Protocol

VOC 1000

Ambient toxic/hydrocarbon analyser

  • ASCII Pushed Protocol

Environics

6100 Calibrator

Support being added

Environnement S.A.

AC31M/AC32M

MODE4/MODE4+

AF21M/AF22M

MODE4/MODE4+

AS32M

MODE4/MODE4+

CO11M/CO12M

MODE4/MODE4+

HC51M

MODE4/MODE4+

MP101M

MODE4/MODE4+

O₃41M/O₃42M

MODE4/MODE4+

VOC71M

MODE4/MODE4+

Gill

Maximet GMX500

Modbus. Must be non-GPS model on default register settings.

WindSonic

Supports all message formats (UV/Polar/NMEA) in continuous and polled mode.
Set the device ID (A to Z) to poll the instrument, or leave blank for continuous mode.

Grimm

EDM 180

Gesytec Protocol

ICP DAS

I7000 Series

7005/7017/7021/7022/7024/7024R/7024U

DCON Protocol

LCJ Capteurs

Wind Sensor

NMEA 0183 Template

Los Gatos Research

Greenhouse Gas Analyser

Magee Scientific

Aethalometer Model AE33

  • Pushed Data Protocol - AE33_data streaming (ID_com=9)

  • Polled Data Protocol - Datalogger_AE33_protocol (ID_com = 5)

  • Bayern-Hessen

    • BH Protocol - Datalogger_BH_protocol (ID_com = 7)

    • BH Protocol 2 - Datalogger_BH_protocol (ID_com = 12)

    • BH Protocol 3 - Datalogger_BH_protocol (ID_com = 13)

Also supports AMES TPR159 external probe.

Met One Instruments Inc.

BAM 1020 Particulate Monitor - 9800

Computer Protocol (Network Id supported)

9803 Touch Screen Variant should also be supported

BAM 1020 Particulate Monitor - 9805

Computer Protocol (Network Id supported)

Minimum firmware required: TBD

BAM 1022

Computer Protocol (Network Id supported)

Tested with firmware 81650, R1.0.7

BC 1054

Black Carbon Monitor

  • ASCII

  • MetRecord Protocol tested with firmware 82401 R3.1.0 on Serial - Note that adding an instrument id automatically switches the protocol to network mode

E-642 Dust Monitor

Computer Protocol (Network Id supported)

Not Currently Available

E-BAM Particulate Monitor

Computer Protocol (Network Id supported)

Tested with firmware 3613-01 R1.57

E-BAM PLUS Particulate Monitor

Computer Protocol (Network Id supported)

Tested with firmware 82102, R1.0.0/82102, R1.1.3/82102, R1.3.0

E-SAMPLER Particulate Monitor

Computer Protocol (Network Id supported)

Tested with firmware 3693-01 R1.19.5/3693-01 R1.19.8/3693-02 R2.0.3/3693-02 R2.0.5

Modbus (Generic)

RTU/TCP

Generic modbus (RTU and TCP) allows a user to define their own register configuration by manually adding user defined parameters for a variety of supported function codes and with the ability to specify the byte order at the instrument level.

Opsis

AR600 / AR650 / LD500

AR600 Multi-component analyser (UV)

AR650 Multi-component analyser (IR)

Palas

Fidas 200

Fine dust aerosol spectrometer - Modbus Template

Picarro

G1301

G4x

Rupprecht and Patashnick (R&P)

TEOM 1400a

AK Protocol

Synspec

GC955

Multi-component analyser for CEMS and process control

Teledyne API

Gas Analyzer

T100 SO2 Analyser

T200 NO / NO2 / NOx Analyser

T400 O3 Analyser

  • Multi-drop protocol

Gas Calibrator

T700 Calibrator

T700U Calibrator

  • Multi-drop protocol

Thermo Fisher

42i/43i/48i/49i

C-Link

5014i

C-Link

ESM ASCII Protocol

Modbus Template

5028i

C-Link

Modbus Template

5030

ESM ASCII Protocol

5030i

ESM ASCII Protocol

FH62C14

ESM ASCII Protocol

Partisol 2025

C-Link

Bayern-Hessen Template

Modbus Template

Needs testing (also supports AK protocol - not implemented)

Sharp 5030

Support being added

TEOM 1400a/1405/1405DF

AK Protocol

Vaisala

H425

Support being added

PTB220

ASCII Protocol

WMT700

Can use WS425 ASCII driver with the WS425 - ASCII profile

WS425

ASCII Protocol

WXT 510

ASCII Protocol

WXT 520

ASCII Protocol

WXT 530 Series

NMEA Protocol

Verewa

F-701-20

Yoctopuce

Yocto-WatchdogDC (Ecotech Congrego Watchdog)

Use “custom” connection.

Zetian

DPM-6000

Modbus Template